Medical waste microwave disposal equipment
$260000/set/t
Microwave disinfection unit for medical waste Model MDU-1B
MDU-1B is an integration system including feeding, shredding, disinfection, discharging, and exhaust ducting systems.
60kg/h treatment capacity, or 600l/h, based on an average density of medical waste at 0.1kg/l ~0.15kg/l.
It can service well to some large scale or medium scale hospitals, clinics, or any other healthcare centers, Customs epidemic prevention department, etc. whose medical waste quantity would be 500kg per day (±10%).
TECHNICAL CHARACTERISTICS
MDU series products are designed as an automatic operation system with minimal operator operations, with the following characteristics:
Energy saving: microwave heating is uniform, no energy loss, high energy, strong penetration into the object, instantaneous penetration into the object, good energy-saving effect, take the model with a daily processing capacity of 5T/d as an example, installed power Only 117 kilowatts.
Efficient energy: The temperature of action is low, and the heat loss is slow: If microwave and ordinary heating produce the same amount of disinfection, the temperature of the object will be significantly lower than that of ordinary heating. The waste after microwave disinfection is non-toxic, without residue, and lightly damaged.
Absolute sterilization and disinfection: Microwave can effectively sterilize all materials on all organisms with no select. It has a broad spectrum of disinfection bacteria and can kill various microorganisms and pathogens.
Spatial convenience: Microwave disinfection requires a small working environment and small area, does not cause high temperature to the surrounding environment, and is clean and hygienic.
Environmental friendly: no acid gas and dioxins and other pollutants are produced.
PARAMETERS
Equipment Model No. |
MDU-1B |
Dimensions (L*W*H) |
5600mm*1900mm*2600mm |
Overall weight |
4000kg |
Required space (L*W*H) |
7000*3500*3000mm |
Installed Power |
45KW (24KW steam generator included) |
Treatment capacity |
60kg/h (medical waste density average 0.1kg/l~0.15kg/l) |
Operation and control |
PLC control, automatic process |
Shredding system |
Double-shaft shredder, automatic reverse system is configured to avoid material blockage. |
Feeding form |
Automatic lifting and charging system contained |
Disinfection temperature |
≥95℃ |
Disinfection duration |
≥45min |
Disinfection effect |
≥4 log10 The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 4.00. |
Microwave frequency |
2450+/-50MHz |
Microwave generator power |
1.25KW * 6unit |
Manpower |
No specialized operator / ONE |